Subba Reddy, B and Nandi, S (2019) Development of HMI based Multi-stresses Aging Facility for Polymeric Insulators. In: 13th International Conference on Industrial and Information Systems, ICIIS 2018, 1 - 2 December 2018, Rupnagar, Punjab, pp. 371-374.
PDF
ICIIS_2018.pdf - Published Version Restricted to Registered users only Download (536kB) | Request a copy |
Abstract
The paper highlights the development of a multi-stress experimental arrangement for the analysis of silicone rubber based polymer insulators used in high voltage transmission, distribution and traction systems. Presently, various controllers and sensors are adopted to establish an automatic experimental set-up for simulating the necessary stresses. The facility is being developed for the first time as per the relevant standards using an HMI (human machine interface), the experimental facility is mainly built to be useful for research and testing activity on different types of components used in transmission and distribution systems.
Item Type: | Conference Paper |
---|---|
Publication: | 2018 13th International Conference on Industrial and Information Systems, ICIIS 2018 - Proceedings |
Publisher: | Institute of Electrical and Electronics Engineers Inc. |
Additional Information: | The copyright for this article belongs to Institute of Electrical and Electronics Engineers Inc. |
Keywords: | Aging of materials; Controllers; Information systems; Information use; Machine components; Sensors; Silicones, Experimental arrangement; Experimental facilities; Experimental set up; High voltage transmissions; Human Machine Interface; Polymer insulator; Polymeric insulators; Transmission and distribution systems, Silicone rubber |
Department/Centre: | Division of Electrical Sciences > Electrical Engineering |
Date Deposited: | 07 Aug 2022 09:18 |
Last Modified: | 07 Aug 2022 09:18 |
URI: | https://eprints.iisc.ac.in/id/eprint/75463 |