The effects of inhomogeneities on scroll-wave dynamics in an anatomically realistic mathematical model for canine ventricular tissue

Rajany, KV and Majumder, R and Nayak, AR and Pandit, R (2021) The effects of inhomogeneities on scroll-wave dynamics in an anatomically realistic mathematical model for canine ventricular tissue. In: Physics Open, 9 .

[img]
Preview
PDF
phy_ope_9_2021.pdf - Published Version

Download (2MB) | Preview
[img] Archive (ZIP)
1-s2.0-S2666032621000326-mmc1.zip - Published Supplemental Material

Download (48MB)
Official URL: https://doi.org/10.1016/j.physo.2021.100090

Abstract

Ventricular tachycardia (VT) and ventricular fibrillation (VF) are lethal rhythm disorders, which are associated with the occurrence of abnormal electrical scroll waves in the heart. Given the technical limitations of imaging and probing, the in situ visualization of these waves inside cardiac tissue remains a challenge. Therefore, we must, perforce, rely on in silico simulations of scroll waves in mathematical models for cardiac tissue to develop an understanding of the dynamics of these waves in mammalian hearts. We use direct numerical simulations of the Hund�Rudy-Dynamic (HRD) model, for canine ventricular tissue, to examine the interplay between electrical scroll-waves and conduction and ionic inhomogeneities, in anatomically realistic canine ventricular geometries with muscle-fiber architecture. We find that millimeter-sized, distributed, conduction inhomogeneities cause a substantial decrease in the scroll wavelength, thereby increasing the probability for wave breaks; by contrast, single, localized, medium-sized (� cm) conduction inhomogeneities, exhibit the potential to suppress wave breaks or enable the self-organization of wave fragments into stable, intact scrolls. We show that ionic inhomogeneities, both distributed or localized, suppress scroll-wave break up. The dynamics of a stable rotating wave is not affected significantly by such inhomogeneities, except at high concentrations of distributed inhomogeneities, which can cause a partial break up of scroll waves. Our results indicate that inhomogeneities in the canine ventricular tissue are less arrhythmogenic than inhomogeneities in porcine ventricular tissue, for which an earlier in silico study (Majumder et al., 2016) has shown that the inhomogeneity-induced suppression of scroll waves is a rare occurrence. © 2021

Item Type: Journal Article
Publication: Physics Open
Publisher: Elsevier B.V.
Additional Information: The copyright for this article belongs to Authors