ePrints@IIScePrints@IISc Home | About | Browse | Latest Additions | Advanced Search | Contact | Help

A Dual Five-Level Inverter-Fed Induction Motor Drive With Common-Mode Voltage Elimination and DC-Link Capacitor Voltage Balancing Using Only the Switching-State Redundancy—Part II

Tekwani, PN and Kanchan, RS and Gopakumar, K (2007) A Dual Five-Level Inverter-Fed Induction Motor Drive With Common-Mode Voltage Elimination and DC-Link Capacitor Voltage Balancing Using Only the Switching-State Redundancy—Part II. In: IEEE Transactions on Industrial Electronics, 54 (5). pp. 2609-2617.

[img]
Preview
PDF
Part_II.pdf

Download (1MB)

Abstract

The open-loop control scheme presented in part I of this paper for a dual five-level-inverter-fed induction motor(IM) drive with two dc power supplies maintains dc-link capacitor voltage balancing and common-mode voltage (CMV) elimination throughout the operating range of the drive. The operating limitation of the proposed open-loop control scheme to take corrective action toward the existing unbalance in the dc-link-capacitor voltages is also pointed out in part I of this paper. As a solution to this, a simple closed-loop control scheme, which is based only on the switching-state redundancy, is proposed in this part of the paper. The proposed closed-loop control scheme not only prevents further unbalancing of capacitor voltages but also takes corrective actions to bring back the capacitor voltages in the balanced state. The proposed closed-loop scheme achieves dc-link capacitor voltage balancing and elimination of CMV together in the complete modulation range, including overmodulation of up to the 24-step operation. The proposed control scheme does not affect the output fundamental voltage generated by the inverter, as it effectively utilizes only the availability of redundant switching states of the inverter, and does not call for additional power circuit hardware. The scheme is presented with the simulation studies and experimentally verified with a 1.5-kW open-end winding IM drive.

Item Type: Journal Article
Publication: IEEE Transactions on Industrial Electronics
Publisher: IEEE
Additional Information: Copyright 2007 IEEE. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.
Keywords: Closed-loop control;common-mode voltage (CMV) elimination;dc-link capacitor voltage balancing;induction motor (IM) drive;multilevel inverter;switching-state redundancy.
Department/Centre: Division of Electrical Sciences > Electronic Systems Engineering (Formerly Centre for Electronic Design & Technology)
Date Deposited: 31 Jul 2008
Last Modified: 19 Sep 2010 04:48
URI: http://eprints.iisc.ac.in/id/eprint/15374

Actions (login required)

View Item View Item