Raghuram, PT and Das, TR (2002) Bubble size measurement in a gas-liquid ejector for a sodium chloride-air system. In: Journal of Chemical Engineering of Japan, 35 (4). pp. 389-392.
Full text not available from this repository. (Request a copy)Abstract
A high speed photographic technique has been employed to measure the Sauter mean diameter of bubbles experimentally in a gas liquid ejector using a sodium chloride-air system. The measured values are compared with the theoretically predicted maximum bubble size diameter using Sprow's correlation. Bubble size as a function of the liquid flow rate and also of its distance from the throat of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those obtained earlier for the air-water system.
Item Type: | Journal Article |
---|---|
Publication: | Journal of Chemical Engineering of Japan |
Publisher: | Japan Science and Technology Information Aggregator, Electronic |
Additional Information: | Copyright of this article belongs to Japan Science and Technology Information Aggregator, Electronic. |
Keywords: | Bubble Size Measurement;Ejector;Photographic Method;Sauter Mean Diameter;Non-reactive System |
Department/Centre: | Division of Mechanical Sciences > Chemical Engineering |
Date Deposited: | 04 Aug 2011 05:04 |
Last Modified: | 04 Aug 2011 05:04 |
URI: | http://eprints.iisc.ac.in/id/eprint/39024 |
Actions (login required)
View Item |