Prakash, K (1996) A new two point method of obtaining Cv from a consolidation test: Discussion. In: Canadian Geotechnical Journal, 35 (05). pp. 849-850.
PDF
A_New_point.pdf - Published Version Restricted to Registered users only Download (253kB) | Request a copy |
Abstract
Careful study of various aspects presented in the note reveals basic fallacies in the concept and final conclusions.The Authors claim to have presented a new method of determining C-v. However, the note does not contain a new method. In fact, the method proposed is an attempt to generate settlement vs. time data using only two values of (t,8). The Authors have used a rectangular hyperbola method to determine C-v from the predicated 8- t data. In this context, the title of the paper itself is misleading and questionable. The Authors have compared C-v values predicated with measured values, both of them being the results of the rectangular hyperbola method.