ePrints@IIScePrints@IISc Home | About | Browse | Latest Additions | Advanced Search | Contact | Help

Browse by Author

Up a level
Export as [feed] Atom [feed] RSS 1.0 [feed] RSS 2.0
Group by: Item Type | No Grouping
Number of items: 50.

Conference Proceedings

Biswas, Bidhan and Satish, L (2017) Analytical computation of any system function of a large-sized fully-coupled ladder network: A symbol-free method. In: 3rd International Conference on Condition Assessment Techniques in Electrical Systems (CATCON), NOV 16-18, 2017, Indian Inst Technol Ropar, Rupnagar, INDIA, pp. 191-196.

Mukherjee, Pritam and Satish, L (2015) Estimation of Severity of Simulated Mechanical Damages in a Single Isolated Transformer Winding. In: International Conference on Condition Assessment Techniques in Electrical Systems (CATCON), DEC 10-12, 2015, Bengaluru, INDIA, pp. 231-235.

Pramanik, Saurav and Satish, L (2013) Enhancing Physical Resolution of Constructed Ladder Network for an Interleaved Winding. In: IEEE 1st International Conference on Condition Assessment Techniques in Electrical Systems (IEEE CATCON), DEC 06-08, 2013, Jadavpur Univ, Elect Engn Dept, High Tens Lab, Kolkata, INDIA, pp. 60-65.

Reddy, Subba B and Naik, Satish B and Kumar, Udaya and Satish, L (2012) Potential and electric field distribution in a ceramic disc insulator string with faulty insulators. In: 10th IEEE International Conference on the Properties and Applications of Dielectric Materials (ICPADM), JUL 24-28, 2012 , Bangalore, INDIA.

Conference Paper

Biswas, B and Bharadwaj, N and Satish, L (2019) Estimation of Series Capacitance of an Actual, Uniform, Single, Isolated Transformer Winding from Measured Driving Point Impedance Data. In: 2019 IEEE 4th International Conference on Condition Assessment Techniques in Electrical Systems (CATCON), 21-23 Nov. 2019, Chennai, India, India.

Satish, L and Subrat, KS (2007) Some Thoughts on Location of Faults along a Transformer Winding. In: CIGRE SC A1 & D1 Joint Colloquium Gyeongju, Korea, Oct 24, 2007, Gyeongju, Korea.

Satish, L and Saravanakumar, A (2007) What Terminal Configuration to Use for SFR Measurements on 1- and 2- Transformers? In: CIGRE SC A1 & D1 Joint Colloquium, Gyeongju, Korea, Oct 24, 2007, Gyeongju, Korea.

Journal Article

Muhammed, A and Satish, L and Kumar, U (2020) Elegant procedure to estimate series capacitance of a uniform transformer winding from its measured FRA: Implementable on existing FRA instruments. In: High Voltage, 5 (4). pp. 444-453.

Biswas, B and Satish, L (2020) Experimental Results on Estimation of Effective Inductance Associated with Winding Resonances of 1- and 3- Transformers Using Measured FRA. In: IEEE Transactions on Power Delivery, 35 (5). pp. 2378-2386.

Biswas, Bidhan and Satish, L (2019) Analytical Expressions to Link SCNF and OCNF of Transformer Windings to Their Inductances and Capacitances for 1-Phi, 3-Phi Y and Delta Configurations. In: IEEE TRANSACTIONS ON POWER DELIVERY, 34 (4, SI). pp. 1725-1735.

Mukherjee, Pritam and Satish, L (2019) Analytical Expression for Resonances of an Inhomogeneous, Radial, Lossless LC Network. In: IEEE TRANSACTIONS ON POWER DELIVERY, 34 (3). pp. 899-909.

Mukherjee, P and Satish, L (2018) Estimating the Equivalent Air-Cored Inductance of Transformer Winding from Measured FRA. In: IEEE Transactions on Power Delivery, 33 (4). pp. 1620-1627.

Mukherjee, Pritam and Satish, L (2017) Diagnosing Axial Displacement in an Actual, Single, Isolated Transformer Winding: Experimental Results. In: IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 24 (2). pp. 1280-1287.

Mukherjee, Pritam and Satish, L (2017) Generalized Analytical Expression for Natural Frequencies of a Single Isolated Air-Core Inhomogeneous Transformer Winding. In: IEEE TRANSACTIONS ON POWER DELIVERY, 32 (5). pp. 2313-2319.

Mukherjee, Pritam and Satish, L (2017) Generalized Analytical Expression for Natural Frequencies of a Single Isolated Air-Core Inhomogeneous Transformer Winding. In: IEEE TRANSACTIONS ON POWER DELIVERY, 32 (5). pp. 2313-2319.

Maulik, Sugoto and Satish, L (2016) Localization and Estimation of Severity of a Discrete and Localized Mechanical Damage in Transformer Windings: Analytical Approach. In: IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 23 (3, SI). pp. 1266-1274.

Mukherjee, Pritam and Satish, L (2016) Localization of Radial Displacement in an Actual Isolated Transformer Winding-An Analytical Approach. In: IEEE TRANSACTIONS ON POWER DELIVERY, 31 (6). pp. 2511-2519.

Pramanik, S and Satish, L (2015) A critical review of the definition of FRA resonance frequency of transformers as per IEEE Std C57.149-2012. In: ELECTRIC POWER SYSTEMS RESEARCH, 121 . pp. 52-57.

Pramanik, Saurav and Satish, L (2014) Correction to "Estimation of Series Capacitance of a Transformer Winding Based on Frequency-Response Data: An Indirect Measurement Approach" (vol 26, pg 2870, 2011). In: IEEE TRANSACTIONS ON POWER DELIVERY, 29 (1). pp. 302-303.

Pramanik, Saurav and Satish, L (2014) Time-Domain Approach to Estimate Series Capacitance of an Isolated Phase Winding of a Transformer. In: IEEE TRANSACTIONS ON POWER DELIVERY, 29 (4). pp. 1939-1945.

Pramanik, Saurav and Satish, L (2013) Estimation of Series Capacitance for a Three-Phase Transformer Winding From Its Measured Frequency Response. In: IEEE TRANSACTIONS ON POWER DELIVERY, 28 (4). pp. 2437-2444.

Mukherjee, P and Satish, L (2012) Construction of Equivalent Circuit of a Single and Isolated Transformer Winding From FRA Data Using the ABC Algorithm. In: IEEE Transactions on Power Delivery, 27 (2). pp. 963-970.

Mukherjee, Pritam and Satish, L (2012) Construction of Equivalent Circuit of a Single and Isolated Transformer Winding From FRA Data Using the ABC Algorithm. In: IEEE Transactions on Power Delivery, 27 (2). pp. 963-970.

Mukherjee, P and Satish, L (2012) Construction of equivalent circuit of a transformer winding from driving-point impedance function - analytical approach. In: IET Electric Power Applications, 6 (3). pp. 172-180.

Pramanik, Saurav and Satish, L (2011) Estimation of Series Capacitance of a Transformer Winding Based on Frequency-Response Data: An Indirect Measurement Approach. In: IEEE Transactions on Power Delivery, 26 (4). pp. 2870-2878.

Pramanik, S and Satish, L (2011) Localisation of discrete change in a transformer winding: a network-function-loci approach. In: IET Electric Power Applications, 5 (6). pp. 540-548.

Vora, Santosh C and Satish, L (2011) ADC Static Nonlinearity Estimation Using Linearity Property of Sinewave. In: IEEE Transactions on Instrumentation and Measurement, 60 (4). pp. 1283-1290.

Vora, Santosh C and Satish, L (2010) ADC Static Characterization Using Nonlinear Ramp Signal. In: Transactions on Instrumentation and Measurement, 59 (8). pp. 2115-2122.

Satish, L and Vora, Santosh C (2010) Amplitude Frequency Response Measurement: A Simple Technique. In: IEEE Transactions on Education, 53 (3). pp. 365-371.

Vora, SC and Satish, L (2009) A Proposal for Concurrent Estimation of Static and Dynamic Nonlinearity of ADC. In: Ieee transactions on power delivery, 24 (2). pp. 524-530.

Vora, Santosh C and Satish, L (2009) A Proposal for Concurrent Estimation of Static and Dynamic Nonlinearity of ADC. In: Ieee Transactions On Power Delivery, 24 (2). pp. 524-530.

Satish, L and Sahoo, Subrat K (2009) Locating faults in a transformer winding: An experimental study. In: Electric Power Systems Research, 79 (1). pp. 89-97.

Ragavan, K and Satish, L (2008) Construction of Physically Realizable Driving-Point Function From Measured Frequency Response Data on a Model Winding. In: IEEE Transactions on Power Delivery, 23 (2). pp. 760-767.

Satish, L and Saravanakumar, A (2008) Identification of Terminal Connection and System Function for Sensitive Frequency Response Measurement on Transformers. In: IEEE Transactions on Power Delivery, 23 (2). pp. 742-750.

Ragavan, K and Satish, L (2007) Localization of Changes in a Model Winding Based on Terminal Measurements: Experimental Study. In: IEEE Transactions on Power Delivery, 22 (3). pp. 1557-1565.

Sahoo, Subrat K and Satish, L (2007) Discriminating changes introduced in the model for the winding of a transformer based on measurements. In: Electric Power Systems Research, 77 (7). 851 -858.

Ragavan, K and Satish, L (2007) Closure on "An Efficient Method to Compute Transfer Function of a Transformer From Its Equivalent Circuit". In: IEEE Transactions on Power Delivery, 22 (2). pp. 1261-1262.

Satish, L and Vora, Santosh C and Sinha, Alok Kumar (2005) A time efficient method for determination of static non-linearities of high-speed high-resolution ADCs. In: Measurement, 38 (2). pp. 77-88.

Ragavan, K and Satish, L (2005) An Efficient Method to Compute Transfer Function of a Transformer from its Equivalent Circuit. In: IEEE Transactions on Power Delivery, 20 (2). 780 -788.

Satish, L and Sahoo, Subrat K (2005) An Effort to Understand What Factors Affect the Transfer Function of a Two-Winding Transformer. In: IEEE Transactions on Power Delivery, 20 (2). pp. 1430-1440.

Satish, L and Nazneen, B (2003) Wavelet-based Denoising of Partial Discharge Signals Buried in Excessive Noise and Interference. In: IEEE Transactions on Dielectrics and Electrical Insulation, 10 (2). 354 -367.

Gururaj, BI and Satish, L (2002) Detection and Localization of Inter-turn Fault in the HV Winding of a Power Transformer using Wavelets- Comment. In: IEEE Transactions on Dielectrics and Electrical Insulation, 9 (3). pp. 479-480.

Satish, L and Jain, Anurag (2002) Structure of Transfer Function of Transformers With Special Reference to Interleaved Windings. In: IEEE Transactions on Power Delivery, 17 (3). pp. 754-760.

Satish, L and Gururaj, BI (2001) Wavelet Analysis for Estimation of Mean-Curve of Impulse Waveforms Superimposed by Noise, Oscillations and Overshoot. In: IEEE Transactions on Power Delivery, 16 (1). pp. 116-121.

Lalitha, EM and Satish, L (2000) Wavelet Analysis for Classification of Multi-source PD Patterns. In: IEEE Transactions on Dielectrics and Electrical Insulation, 7 (1). pp. 40-47.

Pandey, Santosh Kumar and Satish, L (1998) Multiresolution Signal Decomposition: A New Tool for Fault Detection in Power Transformers During Impulse Tests. In: IEEE Transactions on Power Delivery, 13 (4). pp. 1194-1200.

Lalitha, EM and Satish, L (1998) Fractal Image Compression for Classification of PD Sources. In: IEEE Transactions on Dielectrics and Electrical Insulation, 5 (4). pp. 550-557.

Satish, L (1998) Short-time Fourier and wavelet transforms for fault detection in power transformers during impulse tests. In: IEE Proceedings of Science, Measurement and Technology, 145 (2). pp. 77-84.

Satish, L and Gururaj, BI (1993) Partial discharge pattern classification using multilayer neural networks. In: IEE Proceedings of Science, Measurement and Technology, 140 (4). pp. 323-330.

Satish, L and Gururaj, BI (1993) Use of Hidden Markov Models for Partial Discharge Pattern Classification. In: IEEE Transactions on Electrical Insulation, 28 (2). 172 -182.

This list was generated on Tue Apr 16 14:05:28 2024 IST.