Shukla, AK and Kumar, Ganesh V and Munichandraiah, N and Srinath, TS (1998) A method to monitor valve-regulated lead acid cells. In: Journal of Power Sources, 74 (2). pp. 234-239.
PDF
A_method-152.pdf Restricted to Registered users only Download (281kB) | Request a copy |
Abstract
The individual electrode impedance parameters and internal resistance of industrial type 120-Ah valve- regulated lead acid VRLA cells are obtained from a galvanostatic nondestructive technique. The resistive components of the cells are found to be minimum at a state-of-charge SOC value of 0.5. The study reflects that the optimum performance of the VRLA cells is achieved at SOC values between 0.2 and 0.8.
Item Type: | Journal Article |
---|---|
Publication: | Journal of Power Sources |
Publisher: | Elsevier |
Additional Information: | Copyright of this article belongs to Elsevier. |
Keywords: | Valve-regulated lead acid cells;Impedance;State-of-charge |
Department/Centre: | Division of Chemical Sciences > Solid State & Structural Chemistry Unit Division of Chemical Sciences > Inorganic & Physical Chemistry |
Date Deposited: | 09 Jan 2007 |
Last Modified: | 19 Sep 2010 04:34 |
URI: | http://eprints.iisc.ac.in/id/eprint/9431 |