ePrints@IIScePrints@IISc Home | About | Browse | Latest Additions | Advanced Search | Contact | Help

Validation of In-field Calibration for Low-Cost Sensors Measuring Ambient Particulate Matter in Kolkata, India

Nobell, S and Majumdar, A and Mukherjee, S and Chakraborty, S and Chatterjee, S and Bose, S and Dutta, A and Sethuraman, S and Westervelt, DM and Sengupta, S and Basu, R and McNeill, VF (2023) Validation of In-field Calibration for Low-Cost Sensors Measuring Ambient Particulate Matter in Kolkata, India. In: Aerosol and Air Quality Research, 23 (11).

[img] PDF
aer_air_qua_res_23_11_2023 - Published Version

Download (1MB)
Official URL: https://doi.org/10.4209/aaqr.230010

Abstract

Low-cost sensors (LCS) provide opportunities for neighborhood-level air pollution data collection, yet significant knowledge gaps remain regarding the accurate application and interpretation of LCS. In this study, we present an in-field calibration of a network of 20 low-cost ambient particulate matter sensors (LCS) in greater Kolkata, India, operating between October 2018�April 2019. In order to understand LCS performance in relation to local reference-grade PM2.5 monitors (RGMs), three of these LCS were co-located with RGMs operated by the West Bengal Pollution Control Board at Rabindra Bharati University (RBU), Victoria Memorial (VICTORIA), and Padmapukur (Howrah, PDM). Data from the co-locations were used to calibrate the LCS network using random forest regression and multiple linear regression approaches. Measured relative humidity and temperature were significant model features. Agreement between the LCS and RGM for 24-h averaged PM2.5 measurements was strongest at RBU, with an uncalibrated root mean squared error (RMSE) of 27.1 µg m�3, followed by PDM (32.6 µg m�3) and VICTORIA (50.7 µg m�3). Multiple linear regression was used to derive calibration models. Cross-calibration between co-located LCS-RGM pairs was tested. The LCS data after cross-calibration correctly identified days as being in or out of attainment with the 24h National Ambient Air Quality Standard of 60 µg m�3 91 of the time. The corrected data accurately identifies days with an India scale Air Quality Index of �poor� or worse 94 of the time. This suggests that LCS can be a useful supplement to RGM networks for air quality management. Diurnal trends and a high level of correlation across the hybrid LCS-RGM network suggest regional and secondary sources of PM2.5 are important in Kolkata. © The Author(s).

Item Type: Journal Article
Publication: Aerosol and Air Quality Research
Publisher: AAGR Aerosol and Air Quality Research
Additional Information: The copyright for this article belongs to authors.
Keywords: Atmospheric aerosols; Atmospheric humidity; Calibration; Costs; Forestry; Linear regression; Mean square error; Particles (particulate matter); Quality management, Ambient particulate Matter; Co-located; Cross calibration; Data collection; Field calibration; In-field; Low-cost sensors; Neighbourhood; Pm2.5; Urban aerosols, Air quality, aerosol; air quality; ambient air; atmospheric pollution; model validation; particulate matter; sensor; urban pollution, Howrah; India; Kolkata; West Bengal
Department/Centre: Division of Interdisciplinary Sciences > Interdisciplinary Centre for Water Research
Date Deposited: 09 Dec 2024 18:16
Last Modified: 09 Dec 2024 18:16
URI: http://eprints.iisc.ac.in/id/eprint/85382

Actions (login required)