ePrints@IIScePrints@IISc Home | About | Browse | Latest Additions | Advanced Search | Contact | Help

Evaluation of fiber Bragg grating sensor interrogation using InGaAs linear detector arrays and Gaussian approximation on embedded hardware

Kumar, Saurabh and Amrutur, Bharadwaj and Asokan, Sundarrajan (2018) Evaluation of fiber Bragg grating sensor interrogation using InGaAs linear detector arrays and Gaussian approximation on embedded hardware. In: REVIEW OF SCIENTIFIC INSTRUMENTS, 89 (2).

[img] PDF
Rev_Sci_Int_89-2_025102_2018.pdf - Published Version
Restricted to Registered users only

Download (10MB) | Request a copy
Official URL: http://dx.doi.org/10.1063/1.5022548

Abstract

Fiber Bragg Grating (FBG) sensors have become popular for applications related to structural health monitoring, biomedical engineering, and robotics. However, for successful large scale adoption, FBG interrogation systems are as important as sensor characteristics. Apart from accuracy, the required number of FBG sensors per fiber and the distance between the device in which the sensors are used and the interrogation system also influence the selection of the interrogation technique. For several measurement devices developed for applications in biomedical engineering and robotics, only a few sensors per fiber are required and the device is close to the interrogation system. For these applications, interrogation systems based on InGaAs linear detector arrays provide a good choice. However, their resolution is dependent on the algorithms used for curve fitting. In this work, a detailed analysis of the choice of algorithm using the Gaussian approximation for the FBG spectrum and the number of pixels used for curve fitting on the errors is provided. The points where the maximum errors occur have been identified. All comparisons for wavelength shift detection have been made against another interrogation system based on the tunable swept laser. It has been shown that maximum errors occur when the wavelength shift is such that one new pixel is included for curve fitting. It has also been shown that an algorithm with lower computation cost compared to the more popular methods using iterative non-linear least squares estimation can be used without leading to the loss of accuracy. The algorithm has been implemented on embedded hardware, and a speed-up of approximately six times has been observed. Published by AIP Publishing.

Item Type: Journal Article
Publication: REVIEW OF SCIENTIFIC INSTRUMENTS
Publisher: AMER INST PHYSICS, 1305 WALT WHITMAN RD, STE 300, MELVILLE, NY 11747-4501 USA
Additional Information: Copy right for the article belong to AMER INST PHYSICS, 1305 WALT WHITMAN RD, STE 300, MELVILLE, NY 11747-4501 USA
Department/Centre: Division of Electrical Sciences > Electrical Communication Engineering
Division of Physical & Mathematical Sciences > Instrumentation Appiled Physics
Date Deposited: 27 Mar 2018 18:27
Last Modified: 27 Mar 2018 18:27
URI: http://eprints.iisc.ac.in/id/eprint/59397

Actions (login required)

View Item View Item