Hegde, AM and Sitharam, TG (2015) Experimental and numerical studies on protection of buried pipelines and underground utilities using geocells. In: GEOTEXTILES AND GEOMEMBRANES, 43 (5). pp. 372-381.
PDF
Geo_and_Geo_43-5_372_2015.pdf - Published Version Restricted to Registered users only Download (2MB) | Request a copy |
Abstract
This paper presents the results of the laboratory model tests and the numerical studies conducted on small diameter PVC pipes, buried in geocell reinforced sand beds. The aim of the study was to evaluate the suitability of the geocell reinforcement in protecting the underground utilities and buried pipelines. In addition to geocells, the efficacy of only geogrid and geocell with additional basal geogrid cases were also studied. A PVC (Poly Vinyl Chloride) pipe with external diameter 75 mm and thickness 1.4 mm was used in the experiments. The vehicle tire contact pressure was simulated by applying the pressure on the top of the bed with the help of a steel plate. Results suggest that the use of geocells with additional basal geogrid considerably reduces the deformation of the pipe as compared to other types of reinforcements. Further, the depth of placement of pipe was also varied between 1B to 2B (B is the width of loading plate) below the plate in the presence of geocell with additional basal geogrid. More than 50% reduction in the pressure and more than 40% reduction in the strain values were observed in the presence of reinforcements at different depths as compared to the unreinforced beds. Conversely, the performance of the subgrade soil was also found to be marginally influenced by the position of the pipe, even in the presence of the relatively stiff reinforcement system. Further, experimental results were validated with 3-dimensional numerical studies using FLAC(3D) (Fast Lagrangian Analysis of Continua in 3D). A good agreement in the measured pipe stain values were observed between the experimental and numerical studies. Numerical studies revealed that the geocells distribute the stresses in the lateral direction and thus reduce the pressure on the pipe. In addition, the results of the 1-g model tests were scaled up to the prototype case of the shallow buried pipeline below the pavement using the appropriate scaling laws. (C) 2015 Elsevier Ltd. All rights reserved.
Item Type: | Journal Article |
---|---|
Publication: | GEOTEXTILES AND GEOMEMBRANES |
Publisher: | ELSEVIER SCI LTD |
Additional Information: | Copy right for this article belongs to the ELSEVIER SCI LTD, THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, OXON, ENGLAND |
Keywords: | Geosynthetics; Buried pipeline; Geocell; Geogrid; Pavement; Bearing pressure |
Department/Centre: | Division of Mechanical Sciences > Civil Engineering |
Date Deposited: | 03 Sep 2015 04:45 |
Last Modified: | 03 Sep 2015 04:45 |
URI: | http://eprints.iisc.ac.in/id/eprint/52268 |
Actions (login required)
View Item |