Suneetha, TB and Raghuram, PT (2012) Bubble size measurement and error analysis in a gas liquid ejector. In: INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 19 (6). pp. 442-446.
PDF
Ind_Jol_Che_Tec_19-6_442_2012.pdf - Published Version Restricted to Registered users only Download (89kB) | Request a copy |
Abstract
Bubble size in a gas liquid ejector has been measured using the image technique and analysed for estimation of Sauter mean diameter. The individual bubble diameter is estimated by considering the two dimensional contour of the ellipse, for the actual three dimensional ellipsoid in the system by equating the volume of the ellipsoid to that of the sphere. It is observed that the bubbles are of oblate and prolate shaped ellipsoid in this air water system. The bubble diameter is calculated based on this concept and the Sauter mean diameter is estimated. The error between these considerations is reported. The bubble size at different locations from the nozzle of the ejector is presented along with their percentage error which is around 18%.
Item Type: | Journal Article |
---|---|
Publication: | INDIAN JOURNAL OF CHEMICAL TECHNOLOGY |
Publisher: | NATL INST SCIENCE COMMUNICATION-NISCAIR |
Additional Information: | Copyright for this article belongs to NATL INST SCIENCE COMMUNICATION-NISCAIR, NEW DELHI, INDIA |
Keywords: | Bubble size;Error analysis;Gas liquid ejector;Oblate ellipsoid;Prolate ellipsoid;Sauter mean diameter |
Department/Centre: | Division of Mechanical Sciences > Chemical Engineering |
Date Deposited: | 14 Feb 2013 10:55 |
Last Modified: | 14 Feb 2013 10:55 |