Online Computation of Hysteresis Boundary for Constant Switching Frequency Current-Error Space-Vector-Based Hysteresis Controller for VSI-Fed IM Drives

Ramchand, Rijil and Gopakumar, K and Patel, Chintan and Sivakumar, K and Das, Anandarup and Abu-Rub, Haitham (2012) Online Computation of Hysteresis Boundary for Constant Switching Frequency Current-Error Space-Vector-Based Hysteresis Controller for VSI-Fed IM Drives. In: IEEE TRANSACTIONS ON POWER ELECTRONICS, 27 (3). pp. 1521-1529.

[img] PDF
ieee_tran_pow_ele_27-3_2012.pdf - Published Version
Restricted to Registered users only

Download (1MB) | Request a copy
Official URL: http://dx.doi.org/10.1109/TPEL.2011.2120624

Abstract

This paper proposes a current-error space-vector-based hysteresis controller with online computation of boundary for two-level inverter-fed induction motor (IM) drives. The proposed hysteresis controller has got all advantages of conventional current-error space-vector-based hysteresis controllers like quick transient response, simplicity, adjacent voltage vector switching, etc. Major advantage of the proposed controller-based voltage-source-inverters-fed drive is that phase voltage frequency spectrum produced is exactly similar to that of a constant switching frequency space-vector pulsewidth modulated (SVPWM) inverter. In this proposed hysteresis controller, stator voltages along alpha- and beta-axes are estimated during zero and active voltage vector periods using current errors along alpha- and beta-axes and steady-state model of IM. Online computation of hysteresis boundary is carried out using estimated stator voltages in the proposed hysteresis controller. The proposed scheme is simple and capable of taking inverter upto six-step-mode operation, if demanded by drive system. The proposed hysteresis-controller-based inverter-fed drive scheme is experimentally verified. The steady state and transient performance of the proposed scheme is extensively tested. The experimental results are giving constant frequency spectrum for phase voltage similar to that of constant frequency SVPWM inverter-fed drive.

Item Type: Journal Article
Publication: IEEE TRANSACTIONS ON POWER ELECTRONICS
Publisher: IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Additional Information: Copyright for this article belongs to the IEEE
Keywords: Constant switching frequency;current-error space vector;hysteresis control;induction motor (IM) drives
Department/Centre: Division of Electrical Sciences > Electronic Systems Engineering (Formerly Centre for Electronic Design & Technology)
Date Deposited: 30 Jun 2012 07:53
Last Modified: 30 Jun 2012 07:53
URI: http://eprints.iisc.ac.in/id/eprint/44704

Actions (login required)

View Item View Item