Bera, Tushar Kanti and Nagaraju, Jampana (2011) Resistivity imaging of a reconfigurable phantom with circular inhomogeneities in 2D-electrical impedance tomography. In: Measurement, 44 (3). pp. 518-526.
PDF
Resistivity.pdf - Published Version Restricted to Registered users only Download (2MB) | Request a copy |
Abstract
Resistivity imaging of a reconfigurable phantom with circular inhomogeneities is studied with a simple instrumentation and data acquisition system for Electrical Impedance Tomography. The reconfigurable phantom is developed with stainless steel electrodes and a sinusoidal current of constant amplitude is injected to the phantom boundary using opposite current injection protocol. Nylon and polypropylene cylinders with different cross sectional areas are kept inside the phantom and the boundary potential data are collected. The instrumentation and the data acquisition system with a DIP switch-based multiplexer board are used to inject a constant current of desired amplitude and frequency. Voltage data for the first eight current patterns (128 voltage data) are found to be sufficient to reconstruct the inhomogeneities and hence the acquisition time is reduced. Resistivity images are reconstructed from the boundary data for different inhomogeneity positions using EIDORS-2D. The results show that the shape and resistivity of the inhomogeneity as well as the background resistivity are successfully reconstructed from the potential data for single or double inhomogeneity phantoms. The resistivity images obtained from the single and double inhomogeneity phantom clearly indicate the inhomogeneity as the high resistive material. Contrast to noise ratio (CNR) and contrast recovery (CR) of the reconstructed images are found high for the inhomogeneities near all the electrodes arbitrarily chosen for the entire study. (C) 2010 Elsevier Ltd. All rights reserved.
Item Type: | Journal Article |
---|---|
Publication: | Measurement |
Publisher: | Elsevier Science |
Additional Information: | Copyright of this article belongs to Elsevier Science. |
Keywords: | Electrical impedance tomography; Reconfigurable phantom; Inhomogeneity; EIDORS; Contrast to noise ratio (CNR); Contrast recovery (CR) |
Department/Centre: | Division of Physical & Mathematical Sciences > Instrumentation Appiled Physics Division of Physical & Mathematical Sciences > Physics |
Date Deposited: | 09 Mar 2011 04:45 |
Last Modified: | 09 Mar 2011 04:45 |
URI: | http://eprints.iisc.ac.in/id/eprint/35888 |
Actions (login required)
View Item |