Padiyar, KR and Kothari, AG (1989) Analysis Of The Hvdc Turbine Generator Torsional Interactions. In: Electric Machines and Power Systems, 16 (5). pp. 303-317.
Full text not available from this repository. (Request a copy)
Official URL: http://www.informaworld.com/smpp/531810569-5734916...
Abstract
In the recent past it has been found that HVDC transmission systems and turbine-generator shaft torsional dynamics can interact in an unfavourable manner. This paper presents a detailed linearised state space model of AC/DC system to study this torsional interaction. The model developed is used to study the effect of various system parameters, such as, dc line loading, converter firing angle, the firing scheme employed. The results obtained are compared with those given in[3].