Raghuram, PT (2009) Interfacial area measurement in a gas - liquid ejector for a sodium chloride - air system. In: Indian Journal of Chemicla Technology, 16 (3). pp. 278-282.
![]()
|
PDF
IJCT_16(3)_278-282.pdf - Published Version Download (206kB) |
Abstract
Interfacial area measurement has been carried out experimentally by measuring the bubble size and holdup for air-sodium chloride solution system. The size of the bubble is predominantly established by the air hold up. High speed photography technique for bubble size measurement and gamma ray attenuation method for holdup measurements are followed. The measured values are compared with the theoretically predicted values. Interracial area as a function of the liquid flow rate and also its distance from the nozzle of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those of air-water system.
Item Type: | Journal Article |
---|---|
Publication: | Indian Journal of Chemicla Technology |
Publisher: | National Institute of Science Communication and Information Resources |
Additional Information: | Copyright of this article belongs to National Institute of Science Communication and Information Resources. |
Keywords: | Gas-liquid ejector; High speed photography method; Air-sodium chloride system |
Department/Centre: | Division of Mechanical Sciences > Chemical Engineering |
Date Deposited: | 26 Aug 2009 12:13 |
Last Modified: | 19 Sep 2010 05:36 |
URI: | http://eprints.iisc.ac.in/id/eprint/21124 |
Actions (login required)
![]() |
View Item |