Deepti, DJ and Ramanarayanan, V (2006) State of Charge of Lead Acid Battery. In: 3rd India International Conference on Power Electronics, Dec 19-21, 2006, Chennai, India.
PDF
getPDF.pdf - Published Version Restricted to Registered users only Download (473kB) | Request a copy |
Abstract
Lead acid batteries are used in hybrid vehicles and telecommunications power supply. For reliable operation of these systems, an indication of state of charge of battery is essential. To determine the state of charge of battery, current integration method combined with open circuit voltage, is being implemented. To reduce the error in the current integration method the dependence of available capacity as a function of discharge current is determined. The current integration method is modified to incorporate this factor. The experimental setup built to obtain the discharge characterstics of the battery is presented
Item Type: | Conference Paper |
---|---|
Publisher: | IEEE |
Additional Information: | Copyright Of This Article 2006 Belongs To Ieee. Personal Use Of This Material Is Permitted. However, Permission To Reprint/Republish This Material For Advertising Or Promotional Purposes Or For Creating New Collective Works For Resale Or Redistribution To Servers Or Lists, Or To Reuse Any Copyrighted Component Of This Work In Other Works Must Be Obtained From The Ieee. |