Ghosh, Rajesh and Narayanan, G (2008) A Simple Method to Improve the Dynamic Response of Single-Phase PWM Rectifiers. In: IEEE Transactions On Industrial Electronics, 55 (10). pp. 3627-3634.
PDF
2008GL034944.pdf - Published Version Restricted to Registered users only Download (1MB) | Request a copy |
Abstract
A single-phase boost rectifier system with conventional low-bandwidth voltage loop exhibits poor dynamic response. A simple method is presented to improve the dynamic response of the rectifier without affecting its steady-state performance. A fast voltage controller is used to improve the dynamic response of the rectifier. The increased low-frequency ripple at the output of the voltage controller is filtered out using a new filter. Design methodology for the voltage loop is presented. The filter is simple enough for analog and digital implementations. Low input current distortion, fast voltage-loo response, and improved dynamic response against line and load disturbances are demonstrated experimentally on a 300-W digitally controlled boost rectifier operating at a switching frequency of 100 kHz.
Item Type: | Journal Article |
---|---|
Publication: | IEEE Transactions On Industrial Electronics |
Publisher: | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC |
Additional Information: | Copyright for this article belongs IEEE |
Keywords: | AC-DC power conversion; boost rectifier; current control; digital control; dynamic response |
Department/Centre: | Division of Electrical Sciences > Electrical Engineering |
Date Deposited: | 26 Dec 2008 11:14 |
Last Modified: | 19 Sep 2010 04:51 |
URI: | http://eprints.iisc.ac.in/id/eprint/16417 |
Actions (login required)
View Item |