Rao, Achanta Ramakrishna and Bimlesh, Kumar (2008) Scale Up Parameter for Surface Aeration Systems. In: International Journal of Chemical Reactor Engineering, 6 (A66).
PDF
1.pdf - Published Version Restricted to Registered users only Download (213kB) | Request a copy |
Official URL: http://www.bepress.com/ijcre/vol6/A66/
Abstract
Based on the scale up parameter, X (theoretical power per unit volume = $F^{4/3} R^{1/3}$, where F is the impeller Froude number and R is the impeller Reynolds number), it is presented that the said parameter is useful in scaling up the micromixing time in surface aeration systems. Scale up equations correlating X with micromixing time have been presented for the geometrically similar circular surface aeration systems.
Item Type: | Journal Article |
---|---|
Publication: | International Journal of Chemical Reactor Engineering |
Publisher: | The Berkeley Electronic Press |
Additional Information: | Copyright of this article belongs to The Berkeley Electronic Press. |
Keywords: | energy dissipation; Froude number; Reynolds number; surface aeration system; micromixing time |
Department/Centre: | Division of Mechanical Sciences > Civil Engineering |
Date Deposited: | 13 Oct 2008 06:53 |
Last Modified: | 19 Sep 2010 04:50 |
URI: | http://eprints.iisc.ac.in/id/eprint/15983 |
Actions (login required)
View Item |