A cartridge based Point-of-Care device for complete blood count

Abbasi, Usama and Chowdhury, Prasanta and Subramaniam, Sasikala and Jain, Prakhar and Muthe, Nitin and Sheikh, Faisal and Banerjee, Subham and Kumaran, V (2019) A cartridge based Point-of-Care device for complete blood count. In: SCIENTIFIC REPORTS, 9 .

[img]
Preview
PDF
41598_2019_54006_MOESM1_ESM.pdf - Published Supplemental Material

Download (1MB) | Preview
[img]
Preview
PDF
sci_rep_9_2019.pdf - Published Version

Download (4MB) | Preview
Official URL: https://dx.doi.org/10.1038/s41598-019-54006-3

Abstract

We demonstrate a proprietary lab-on-chip/mu TAS technology platform for a regulatory grade portable instrument for complete blood count (CBC) hematology tests including 3 part differential WBCs, RBCs, platelet and hemoglobin for rapid diagnostics at the point of care in resource-poor settings. Presently, diagnostics based on blood tests are confined to centralized laboratory settings, dependent on large footprint and expensive cytometers or on a microscope, requiring trained laboratory technicians. Consequently, such facilities are not present in rural and semi-urban settings, where there are opportunities and challenges in delivering efficient healthcare infrastructure at an affordable cost in resource-challenged environments. Our proposed design leverages advances in microfluidics and lab-on-chip fabrication techniques to miniaturize the conventional cytometer and bring down the cost significantly. The device can be operated autonomously, without skilled manpower, by primary healthcare professionals in the field and by patients (like glucose self-test devices). The instrument consists of a single-use chip, the size of a credit card, pre-loaded with reagents, in which the sample is loaded, and which is fluidically insulated from the environment. The controller, the size of a toaster, performs the necessary fluid handling and the impedance measurements to deliver the results in minutes.

Item Type: Journal Article
Additional Information: Copyright of this article belongs to NATURE PUBLISHING GROUP
Keywords: TRANSITION REYNOLDS-NUMBER; DYNAMICAL INSTABILITY; MICROFLUIDIC SYSTEMS; SURFACE MODIFICATION; VALVES; MICROFABRICATION; FABRICATION; CYTOMETER; PUMPS
Department/Centre: Division of Mechanical Sciences > Chemical Engineering
Autonomous Societies / Centres > Society for Innovation and Development
Depositing User: Id for Latest eprints
Date Deposited: 14 Jan 2020 07:38
Last Modified: 14 Jan 2020 07:38
URI: http://eprints.iisc.ac.in/id/eprint/64254

Actions (login required)

View Item View Item